MF60 - data logger: |
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
Micron Series Data Logger
|
|
|
|
|
GENERAL
Micron's Data Logger is a versatile instrument for conditioning and storing signals under a wide variety of conditions. It uses a building-block architecture that allows the logger to be configured to meet the exact needs of high volume users, as well as providing a variety of off-the-shelf configurations.
The Data Logger is housed in an aluminum or plastic NEMA-4 container. A Serial Interface Adapter (SIA) provides the interface between the Data Logger and the host computer.
The Data Logger records from one to eight channels of information from connected sensors. Sampling rate, start and stop times are user definable from once per second to once every 18.2 hours. The Data Logger operates from a self contained 9 volt battery and is totally autonomous once the
Data Logger setup information has been uploaded to memory.
|
|
|
|
|
|
|
|
|
|
FEATURES
1 to 8 active channels, 12-bit resolution, minimal data skew.
Non-volatile memory will survive complete power loss
without losing data.
Power consumption is 350 mAH per year of operation.
Logging intervals from 1 second to 18 hours.
Delayed start option to 194 days with 1 second increments.
Local battery (9V) or external power inputs (7-15 VDC).
8 channels total, configured in four pairs.
Constant voltage or constant current Excitation supplies
for each pair of channels.
Fixed gains and offset voltages correctable in software.
Windows 95 (NT and CE available soon).
Complete setup and download functions. Data is stored as
a memory image, and in standard Comma Separated
Variable format compatible with all spread-sheets and
databases.
All calibration and test identification is stored in non-volatile
logger memory.
Multiple level access via passwords.
Real time utility for displaying current measurements
used for checking logger operations for calibration of
sensors. |
|
|
|

Constant Current Excitation
8 channels at 12 bits, memory to 81,920 samples, 1 sec to 18 hrs.
per scan. It is a dedicated data logger set up internally for specific sensors, although it can be adapted for most sensor types. Very low power consumption, up to 1 year off of 1
internal battery.
|
|
|
|
|
|
|
|
|
|
|
|

Constant Voltage Excitation
8 channels at 12 bits, memory to 81,920 samples, 1 sec to 18 hrs.
per scan. It is a dedicated data logger set up internally for specific sensors, although it can be adapted for most sensor types. Very low power consumption, up to 1 year off of 1 internal battery.
|
|
|
|
|
|
|
|
|
|
|
|

Passive Back plane Logger
Designed for flexibility and will accept a wide variety of
plug-in signal conditioners and logger engines. It has 8
channels at 12 bit resolution, memory to 114,688 samples, 1
scan/sec to 1 scan/18 hrs. |
|
|
|
|
|
|
|
|
|
 |
|
Toll
Free: (888) 738-0039
E-mail: a-kast@on.aibn.com
Copyright © 2000 A-KAST Measurements & Control Limited
                  |
|