MM50/MW50 SMART
METER

GENERAL
Micron Meter's MM50 Programmable Smart Panel Meter is
like getting up to 6 meters at the price of one. Display DC
Voltage, current, strain or process signals. Choose input from 2 RTD
types, 6 thermocouples, AC (true RMS)
voltage and current or low level load cells signals. Functional
programming by front panel push buttons.
Input signals may be displayed as voltage or current, or
scaled five full digits from 0 to 99,999 to read directly in engineering units
such as ft./lbs, rpm, psi, etc. No calibration equipment is required when
changing ranges; all ranges are digitally pre-calibrated at the factory.
Temperature scales (Celsius or Fahrenheit) are selectable from the front panel.
The MM50 has fast control response (60 readings/sec), true peak reading
capability, and an analog output that accurately tracks the signal input. It has
an adaptive digital filter that automatically selects the best time constant for
minimum noise, and yet responds rapidly to an actual change in signal level.
Isolated 5,10, or 24 Vdc outputs are available to power strain gages and
transmitters, eliminating the need for an external power supply. The setpoints
for the two alarm indicators are also front panel programmable, and optional
transistors or dual 8 Amp relays can be added to provide control outputs. These
outputs can be set to operate above or below the setpoint, in a latched or
non-latching mode.
Analog outputs are available to drive chart recorders, remote displays or to
transmit to a central control room.
You can even add an RS232 or RS485 interface and communicate directly
with PLC's or computers. Baud rates can be set from 300 to 19,200. We
supply the software to make meter setup fast and easy. We also offer a
Palm Pilot kit for entering setup data
in the field. Three state, parallel BCD outputs are also
available. |
|
|
|
|
| |
|
Standard Features |
-
Plug in Option Boards
-
Five Full Digits Bidirectional
-
50-60 Readings Per Second
-
True Peak Hold, Auto Tare, and
Automatic Adaptive Digital Filter
-
Isolated 5,10, or 24 VDC
Excitation
-
Worldwide AC/DC Power
-
NEMA 4 Lens Cover
-
0.56" High Digits
-
User Selectable Scaling, Front
Panel Programming
|
|
MW50 Features |
- Auto Zeroing
- 5 Digit Resolution to 99.999
- Net and Gross Weight by Reset Button
- Auto Tare or Manual Tare with Tare Value Stored in
Non-Volitile
Memory
- Count by 1,2,5,10,20,50, and 100
- Push-button Scale Calibration Using "0" and
"Known Weight"
- Selectable Dummy Right Hand Zero Allows Display up to 999.990
- Setpoint Control with "Dribble" Factor Compensation for Filling
Applications
|
|
Optional Features |
- Dual 8 AMP Relay Alarm Board
- Open Collector Outputs
- Isolated RS232 or RS485 or Parallel BCD Computer
Interface
- Analog Outputs 0-20 mA, 4-20 mA, or 0 to 10 Volts
DC
|
|
Selectable Signal
Conditioning |
(Choice of One)
- DC Volts (200 mV to 660 V) Current (2 mA-5 A)
- True RMS Volts (200 mV to 660 V) Current (2 mA-5
A)
- Temperature J, K, T, E, R, S Thermocouple
- Temperature 100 OHM RTD with 2,3,4 Wire
Connection.
- DIN 0.00385 or ANSI 0.003925 ALPHA's
- 4 and 6 Wire Bridge Circuit Connections
|
|
Display |
|
Model: MM50 |
5 LED, 7-segment, 14.2mm |
|
Model: MW50 |
6 LED, 7-segment, 14.2mm (.56") high digits and 3 LED
indicators |
|
Color |
Red or Green |
|
Range |
-99999 to +99999 and
-99990 to +99990 |
| |
|
A to
D Conversion |
|
Technique (Pat. 5,262,780) |
Concurrent Slope TM |
|
Rate |
60/s at 60 Hz; 50/s at 50 Hz |
|
Output Update Rate |
56/s at 60 Hz;
47/s at 50 Hz |
|
Display Update Rate |
3.5/s at 60 Hz;
3/s at 50 Hz |
| |
|
Accuracy at 25°C |
|
DC Volts, Amps, Ratio |
0.01% FS ±1Ct. |
|
Thermocouple |
0.3°C max. |
|
RTD |
0.06°C max. |
|
True RMS (1 to 100%) |
0.1% FS, 10 Hz to 10 kHz |
|
Load Cell Meter |
0.01% FS ±1 Ct. |
|
Span Tempco |
0.003% of reading/°C |
|
Load Cell Meter |
0.0015% of reading/°C |
|
Zero Temco |
0.1 Cts./°C |
|
Reference Junction |
0.03 degree/degree |
| |
|
Noise Rejection |
|
CMV from DC to 60 Hz |
Safety-rated to 250 Vac 4.2 kVp per
High Voltage Test |
|
CMR from DC to 60 Hz |
130 dB |
|
NMR to 50/60 Hz Line |
90 dB with minimum filtering |
| |
|
Environmental |
|
Operating Temperature |
0°C to 55°C |
|
Storage Temperature |
-40°C to 85°C |
|
Relative Humidity |
95% at 40°C, non-condensing |
| |
|
Operating Power |
|
Voltage (std.) |
85 to 264 Vac, 90 to 370 Vdc |
|
Voltage (opt.) |
8 to 28 Vac, 9 to 37 Vdc |
|
Frequency |
DC and 47 to 440 Hz |
| |
|
Excitation Power Supplies |
|
Outputs |
5 Vdc, 5%, 100 mA max.
10 Vdc, 5%, 120 mA max.
24 Vdc 5%, 50 mA max. |
|
Isolation (power gnd.) |
Safety-rated to 250 Vac
4.2 kVp per High Voltage Test |
| |
|
Mechanical |
|
 |
|