HOME

Search

Contact info.

  Data Acquisition
  Capacitance sensors
 
 
MP5X Threaded Mount Pressure Transducer

GENERAL

Sensors available as constant voltage (5.0 VDC excitation and 20 mV/V full-scale output) or constant current (4.0 mA excitation and 27 mV/mA output).

Model Excitation Thread
MP50 Constant
 Voltage
10-32 machine thread
MP52 Constant
Current
10-32 machine thread
MP54 Constant
Voltage
Pressure port per MS33656-4
MP55 Constant
Current
Pressure port per MS33656-4
MP56 Constant
Voltage
1/8-27 NPT Pipe Thread
MP57 Constant 
Current
1/8-27 NPT Pipe Thread
MP58 Constant
Voltage
1/2-20 machine thread
MP59 Constant
Current
1/2-20 machine thread

  
    Threaded Mount
    Pressure Transducer


APPLICATIONS

  • TEST & MEASUREMENT EQUIPMENT
  • PRODUCTION EQUIPMENT & CONTROLS
  • ENERGY CONTROLS
  • LABORATORY INSTRUMENTS & EQUIPMENT
  • LIQUID LEVEL
  • CALIBRATION EQUIPMENT


MECHANICAL

Standard Pressure Ranges 300, 500, 1K, 2K, 3K, 5K psi
Non Standard Pressure Ranges 50, 100, 150, 200, 250, 10K psi
Other ranges possible Consult Factory
Over Pressure (No change out of spec.) 2.0x Range
Usable Pressure (Small change in balance) 3.0x Range
Burst Pressure 6.0x Range


PERFORMANCE OPTIONS (ALL VALUES MAXIMUM)

Specification Options
A B C D Units
Balance (Zero) ±3.00 ±2.00 ±2.00 ±2.00 mV
Full Scale Sensitivity
(MP50, MP54, MP56, MP58)
20.0
±2.00
20.0
±2.00
20.0
±2.00
20.0
±2.00
mV /V
Full Scale Sensitivity
(MP52, MP55, MP57, MP59)
27.0
±1.40
27.0
±1.40
27.0
±1.40
27.0
±1.40
mV/mA
Static Error Band ±0.50 ±0.25 ±0.25 ±0.25 %FS BFSL*
Thermal Balance (Zero) Shift ±0.02 ±0.02 ±0.01 0.005 %FS/°F
Thermal Sensitivity Shift 0.02 ±0.02 ±0.01 ±0.005 %FS/°F
*BFSL=Best Fit Straight Line

ENVIRONMENTAL

Storage and Operating Temperature 0° -180°F
Compensated Temperature Range 30° - 130°F
Other Temperature Compensated Ranges Consult Factory
Acceleration 100g's any axis (Ask us for high vibration options)
Media Compatibility (wetted surface) Liquids & Gases compatible with Titanium 6AL4V

ELECTRICAL

Input Constant Voltage Excited
(MP50, MP54, MP56, MP58)
5.0 Volts DC or AC
Input Constant Current Excited
(MP52, MP55, MP57, MP59)
4.0 mA DC or AC
Maximum Voltage 30 V for short periods
Input Resistance (Nominal) 1400 ± 400 Ohms (MP50, MP54, MP56, MP58);
725 ±200 Ohms (MP52, MP55, MP57, MP59)
Output Resistance (Nominal) 850 ± 200 Ohms (MP50, MP54, MP56, MP58);
600 ± 150 Ohms (MP52, MP55, MP57, MP59)
Insulation Resistance Minimum 50 MOhms @ 50 VDC

 